Resources > OCOSH Classification > Orthopaedic Procedures > Arthroplasty > Replacement Arthroplasty > Hip Replacement Arthroplasty > Page 3
Hip Replacement Arthroplasty (Subscribe)
Categories
- Hip Hemireplacement (2)
- Resources relating to hip hemireplacement arthroplasty
- Hip Resurfacing Arthroplasty (1)
- Internet resources relating to Hip Resurfacing Arthroplasty
Links
National Institue of Clinical Excellence - Hip Prosthesis
http://www.nice.org.uk/cat.asp?c=510Nerve Injury in THR Wheeless
http://www.wheelessonline.com/ortho/nerve_injuries_in_thrPrimary total hip replacement
http://www.rcsed.ac.uk/journal/svol1_6/10600004.htmlG. Bannister BUPA Glen Hospital, Redland Hill, Durdham Down, Bristol, BS6 6UT Surg J R Coll Surg Edinb Irel., 1 December 2003, 332-341
Reassessment of the Usefulness of Frozen Section Analysis for Hip and Knee Joint Revisions Medscape
http://www.medscape.com/viewarticle/580470William A. Kanner, MD; Khaled J. Saleh, MD, MSc, FRSC(C); Henry F. Frierson, Jr, MD Am J Clin Pathol. 2008;130(3):363-368.
Revision Total Hip Replacement Wheeless
http://www.wheelessonline.com/ortho/__100Strain Analysis of the Proximal Femur After Total Hip Replacement
http://www.aboutjoints.com/physicianinfo/topics/strain/strainanalysis. ...Strain analysis of human cadaver femora after cemented total hip arthroplasty (THA) has demonstrated a reduction in stress transfer along the proximal femur. The principal objective of this study was to determine the effect of the cementless application of a press-fit, porous-coated prosthesis on the strain experienced by the proximal femur. Using the photoelastic coating technique (PECT), five human cadaver specimens were subjected to strain analysis before and after cementless arthroplasty with a PCA total hip prosthesis. After total hip replacement, the strain magnitudes were reduced for all points along the medial border when the femur was subjected to loading conditions. A reduction of the level of strain ex�perienced by the calcar ranged from 34.7 to 43.7% under loads ranging from 750 to 2000 N— a considerably smaller reduction than that reported by previous investigators. The region of the greater trochanter was the only area of the lateral surface to demonstrate an increase in strain magnitude after THA; the other, more distal points laterally experienced a reduced level of strain. Increases in strain magnitude, although not statistically significant, were detected along the anterior aspect of the femora. Significant decreases in strain were observed at the two more distal points posteriorly, with no significant change proximally. As this investigation is an evaluation only of the immediate effect of the design of the prosthesis in achieving a press fit, and the specimens are without the benefit of bony ingrowth, additional studies are necessary to determine the effect of biologic ingrowth on the distribution of strain within the proximal femur.
Swedish Hip Arthroplasty Documents Page
http://www.jru.orthop.gu.se/documents.htmSwedish Hip Arthroplasty Register
http://www.jru.orthop.gu.se/THR in the Dysplastic Hip
http://www.wheelessonline.com/ortho/thr_in_the_dysplasic_hip- acetabular rim syndrome: - results from dysplastic hip, which stresses the labrum, resulting in labral degeneration;
- hip arthroscopy and debridement in these patients may provide the patient w/ a few additional years before total hip arthroplasty is required;
Wheeless' Textbook of Orthopaedics
Types of Femoral Stem Loosening Wheeless
http://www.wheelessonline.com/ortho/types_of_femoral_stem_looseningUrinary Excretion Levels of Metal Ions in THR with porous coated implants
http://www.aboutjoints.com/physicianinfo/topics/urinarychapter/urinary ...In: Quantitative Characterization and Performance of Porous Implants for Hard Tissue Applications, ASTM STP 953 J. E. Lemons, Ed., American Society for Testing and Materials, Philadelphia, 1987, pp. 151—162.
by Lynne C. Jones, David S. Hungerford, Robert V. Kenna, Guy Braem, and Virginia Grant
Porous-coated prostheses implanted without bone cement are currently being evaluated for use in patients undergoing total joint replacement (TJR). One parameter under study is the potential release of metal ions from these prostheses. In order to determine if there is a systemic increase in cobalt, chromium, or nickel levels within the body subsequent to total joint replacement with a porous-coated prosthesis, 24-h urine specimens were collected from patients prior to and subsequent to TJR with a PCA total hip prosthesis. Metal ion analysis was achieved using flameless atomic absorption spectroscopy. Increases in urinary cobalt and nickel excretion were detected in several patients at six months and in most patients at one year after surgery. However, these differences were not statistically significant. No differences between the preoperative and postoperative time periods (one week, six months, and twelve months) were detected for urinary levels of chromium. Although the metal ion levels for all of the patients studied appear to be in the range handled by the body’s systemic compensatory mechanisms, which adjust levels of trace elements, continued follow-up is needed to determine the patterns and the long-term significance of metal ion release.



